02 / INDUSTRIAL PIPING

Repair and replacement of water piping in buildings and factories

Rust, seepage or a flexible joint that is starting to fail? We inspect, repair and replace chilled-water and cooling-water piping, and plan the work around your building’s available shutdown window.

What we check before recommending a repair

We look for the source of the leak, then check the adjoining pipe, valves, flanges, flexible joints and supports. Where metal wall loss is suspected, ultrasonic thickness measurements can help define how far the inspection should go.

The findings help you decide which items can be repaired locally and which sections need replacement. We use that scope to plan isolation, draining and post-installation leak checks.

START WITH THE SYMPTOM

Pipe Condition Check

Choose the pipe system, material and problem you’re seeing. You can include the checklist when you ask for a quote.

Sample data

Pipe age helps prioritize inspection. Use actual condition and operating requirements to plan repair. Fitness for continued service and remaining life require an engineering assessment.

What the work can include

Cooling Water Piping

Review routing, equipment connections and shutdown constraints.

Chilled Water Piping

Review tie-ins, pipe sizing, supports and insulation interfaces.

Steel & Stainless Steel Piping

Check material grade, wall thickness and joining method against service conditions.

HDPE Piping

Review pipe size, SDR, jointing method, routes and supports.

Valve Installation & Replacement

Check valve type, pressure class, size and connection dimensions.

Flexible Joint Replacement

Check face-to-face length, flange standard and operating conditions.

Piping Modification & Repair

Assess leaks, damaged connections or supports and define the repair and inspection scope.

What to know before starting

PIPING & WATER SYSTEMS

Piping & valves

Installation, replacement and upgrades for water-system pipework. From routing and tie-ins to valves and supports, we plan around your site and shutdown window.

Existing rooftop water piping and connections below a cooling tower
Existing rooftop water piping and connections below a cooling tower
01

HDPE & water-system piping

Review routes, sizes, materials and existing-system tie-ins, with installation and rerouting to project requirements.

02

Valves, flanges & connections

Replace valves, flexible connectors, gaskets and flange assemblies after checking fluid and operating conditions.

03

Existing-system upgrades

Assess leaks, damaged components and supports, then define the work scope, acceptance checks and site schedule.